3D Printed Adult Male Humeral Bone Models/Check Print Settings

| Parent | 3D Printed Adult Male Humeral Bone Models |
|---|
Check Print Settings
[edit | edit source]| # | Print Setting for Fused Filament Fabrication 3D Printer | Reference Screenshot | Check the most appropriate response for Model #1 | Check the most appropriate response for Model #2 | Why This Matters |
|---|---|---|---|---|---|
| 1 |
Filament Material: PLA AT ALL ORIGINAL DEFAULT SETTINGS |
Done Correctly Done Incorrectly Not Done |
Done Correctly Done Incorrectly Not Done |
| |
| 2 |
Support: NONE |
Done Correctly Done Incorrectly Not Done |
Done Correctly Done Incorrectly Not Done |
| |
| 3 |
Layer Height: 0.15 - 0.3 mm OR LESS Wall Thickness: 5.5 mm (THIS CHANGES THE WALL LINE COUNT) |
Done Correctly Done Incorrectly Not Done |
Done Correctly Done Incorrectly Not Done |
| |
| 4 |
Top Layers: 0 Bottom Layers: DEFAULT VALUE (NOT 0) |
Done Correctly Done Incorrectly Not Done |
Done Correctly Done Incorrectly Not Done |
| |
| 5 |
Infill Density: 15% Infill Pattern: TRI-HEXAGON |
Done Correctly Done Incorrectly Not Done |
Done Correctly Done Incorrectly Not Done |
| |
| 6 | Top/Bottom Speed: 15.0 mm/s |
Done Correctly Done Incorrectly Not Done |
Done Correctly Done Incorrectly Not Done |
| |
| 7 |
Build Plate Adhesion Type: NO RAFT |
Done Correctly Done Incorrectly Not Done |
Done Correctly Done Incorrectly Not Done |
| |
| 8 |
Filament: WHITE PLA JUST FRESH OUT OF SEALED PACKAGING |
Done Correctly Done Incorrectly Not Done |
Done Correctly Done Incorrectly Not Done |
| |
| 9 |
Print Speed on 3D Printer Control Screen: 100% or less |
Done Correctly Done Incorrectly Not Done |
Done Correctly Done Incorrectly Not Done |
|
Acknowledgements
[edit | edit source]This work is funded by a grant from the Intuitive Foundation. Any research, findings, conclusions, or recommendations expressed in this work are those of the author(s), and not of the Intuitive Foundation.
References
[edit | edit source]- ↑ 1.0 1.1 www.prusa3d.com/file/370474/technical-data-sheet.pdf
- ↑ 2.0 2.1 https://support.ultimaker.com/hc/en-us/articles/360011962720-Ultimaker-PLA-TDS
- ↑ 3.0 3.1 Ultimaker. Ultimaker PLA Technical Data Sheet [Internet]. Ultimaker Support. [cited 2021 July 29]. Available from: https://support.ultimaker.com/hc/en-us/articles/360011962720-UltimakerPLA-TDS.
- ↑ 4.0 4.1 Vian, Wei Dai and Denton, Nancy L., "Hardness Comparison of Polymer Specimens Produced with Different Processes" (2018). ASEE IL-IN Section Conference. 3. https://docs.lib.purdue.edu/aseeil-insectionconference/2018/tech/3
- ↑ 5.0 5.1 Society For Biomaterials 30th Annual Meeting Transactions, page 332. Femoral Cortical Wall Thickness And Hardness Evaluation. K. Calvert, L.A. Kirkpatrick, D.M. Blakemore, T.S. Johnson. Zimmer, Inc., Warsaw, IN.
- ↑ https://support.ultimaker.com/hc/article_attachments/4800377696540/Ultimaker-ABS-TDS-v5.00.pdf
- ↑ https://support.ultimaker.com/hc/en-us/article_attachments/360026416800/ultimaker-PETG-SDS-v1.00.pdf
- ↑ https://support.ultimaker.com/hc/en-us/article_attachments/360010204279/SDS_CPE__v3.004-en.pdf
- ↑ https://support.ultimaker.com/hc/article_attachments/4800535847708/Ultimaker-CPE-PLUS-TDS-v5.00.pdf
- ↑ https://support.ultimaker.com/hc/en-us/article_attachments/4777237744540/Ultimaker-PETG-TDS-v1.00.pdf
- ↑ Meema HE, Meema S. Measurable roentgenologic changes in some peripheral bones in senile osteoporosis.J Am Geriat Soc 1963;11:1170-82.
- ↑ Forrest AM, Johnson AE, inventors; Pacific Research Laboratories, Inc., assignee. Artificial bones and methods of making same. United States patent 8,210,852 B2. Date issued 2012 Jul 3.
- ↑ National Institutes of Health Osteoporosis and Related Bone Diseases National Resource Center. What is Bone? [Internet]. Bethesda (MD): The National Institutes of Health (NIH); 2018. [Cited 2021 Aug 17]. Available from: https://www.bones.nih.gov/health-info/bone/bone-health/what-is-bone.
- ↑ 14.0 14.1 https://support.ultimaker.com/hc/en-us/articles/360011952740
- ↑ https://support.ultimaker.com/hc/en-us/articles/360012101319-How-to-store-material
| Authors | Medical Makers |
|---|---|
| License | CC-BY-SA-4.0 |
| Organizations | User:Medical Makers |
| Cite as | Medical Makers (2022–2025). "3D Printed Adult Male Humeral Bone Models/Check Print Settings". Appropedia. Retrieved June 14, 2026. |