Assessment Rubric: Orthopedic Surgical Equipment Set Up and Assistance – Perioperative Nursing (ECSACONM)

[edit | edit source]

Overview

[edit | edit source]

This page provides a psychomotor assessment rubric for managing orthopedic surgery, developed for perioperative nursing training under ECSACONM (East, Central and Southern Africa College of Nursing). It accompanies the corresponding psychomotor skills practice worksheet and is used to assess learner performance across each step.

Each step is assessed by one of two methods. Articulated steps are scored as either "Not done" (clinically unacceptable / not performed) or "Done" (excellent), with no intermediate levels. Observed steps are scored on a five-point scale, with performance anchors defined at level 1 (clinically unacceptable / not performed), level 3 (clinically acceptable / performed), and level 5 (excellent); levels 2 and 4 represent performance between the defined anchors.

Assessment Rubric

[edit | edit source]
# Step Name Assessment Method 1 – Clinically Unacceptable / Not Performed 2 3 – Clinically Acceptable / Performed 4 5 – Excellent Comments
1 Gather supplies Articulated Not done Done
2 Perform hand hygiene and don sterile gown and gloves Articulated Not done Done
3 Set up sterile instrument table Observed Instrument table is disorganized, implants and instruments are mixed, items are difficult to locate, or sterility is compromised. Instruments, implants, and fixation components are organized logically by function and anticipated use while maintaining sterility. Instrument layout is highly organized, supports efficient orthopedic workflow, anticipates procedural progression, and allows immediate access to all required items without searching.
4 Set up and test orthopedic drill Observed Drill is improperly assembled, wrong drill bit is selected, attachments are unsecured, functionality is not tested, or backup equipment is unavailable. Drill is assembled correctly, tested successfully, proper attachments are secured, and backup equipment is available. Drill system is assembled efficiently, all safety checks are completed proactively, rotation/function are verified, and backup systems are confirmed without prompting.
5 Prepare pins, rods, clamps, and external fixator components Observed Components are disorganized, incorrect sizes are selected, compatibility is not verified, or defects are missed. Pins, rods, clamps, and connectors are organized appropriately, inspected, and verified for compatibility and readiness. Components are organized systematically by type and size, defects are identified proactively, and all likely required options are prepared efficiently.
6 Load and verify suction and irrigation setup Observed Suction or irrigation systems are improperly connected, not tested, nonfunctional, or unavailable when needed. Suction and irrigation systems are connected, tested, functional, and positioned appropriately for use. Equipment is assembled efficiently, flow is verified, tubing is secured, and systems are positioned to support uninterrupted workflow.
7 Assist with draping and limb positioning Observed Limb is inadequately positioned, drapes are insecure or contaminated, exposure is inadequate, or sterility is compromised. Limb is positioned appropriately, drapes are secure, exposure is adequate, and sterility is maintained. Limb positioning optimizes both surgical access and imaging access, adjustments are anticipated appropriately, and sterility is maintained throughout.
8 Assist during drilling and pin insertion Observed Required instruments are unavailable when needed, workflow is disrupted, assistance is delayed, or organization is poor. Required instruments and supplies are available when needed, workflow is maintained, and assistance supports the procedure appropriately. Anticipates procedural needs accurately, provides instruments smoothly and efficiently, and supports uninterrupted drilling and pin insertion workflow.
9 Assist with external fixator frame assembly Observed Incorrect components are provided, assembly sequence is not supported, or workflow is significantly delayed. Correct components are provided in an appropriate sequence and assembly proceeds without unnecessary delays. Consistently anticipates assembly requirements, provides components proactively, and supports efficient and accurate frame assembly.
10 Maintain sterile field and organize used/unused instruments Observed Frequently loses organization of the sterile field, mixes used and unused instruments, or fails to recognize contamination or accountability issues. Maintains an organized sterile field, appropriately separates used and unused instruments, preserves sterility, and maintains instrument accountability with only minor corrections. Consistently maintains exceptional organization throughout the procedure, proactively reorganizes the sterile field as workflow changes, immediately recognizes and manages contamination risks, and maintains excellent instrument and implant accountability independently.
11 Perform post-procedure management of orthopedic instruments and implants Articulated Not done Done

References

[edit | edit source]


Page data
Keywords surgery, health
SDG SDG03 Good health and well-being
Authors Ian-laurel
License CC-BY-SA-4.0
Organizations SELF, ECSACONM
Language English (en)
Related 0 subpages, 1 pages link here
Views 2 page views (analytics)
Created July 29, 2026 by Ian-laurel-1
Last edit July 29, 2026 by StandardWikitext bot
Cookies help us deliver our services. By using our services, you agree to our use of cookies.