1

A patient suddenly becomes unresponsive during surgery. The ECG monitor displays ventricular fibrillation. What should the perioperative team do first?

Begin CPR immediately while another team member retrieves and prepares the AED
Wait until the AED is attached before beginning CPR
Confirm ventricular fibrillation using another monitor before intervening
Move the patient to the recovery room before beginning resuscitation

2

Why should chest compressions continue while another team member prepares the AED?

To prevent the AED from restarting its rhythm analysis
To maintain blood flow to vital organs until rhythm analysis or shock delivery is required
To improve adhesion of the AED pads
To reduce battery consumption

3

Which situation requires an alternative anterior-posterior pad configuration?

The patient has excessive chest hair
The patient has an implanted pacemaker
The recommended left lateral pad position is obstructed by the operative field or sterile drapes
The patient is receiving supplemental oxygen

4

During rhythm analysis, the AED operator announces, "Clear." What is the primary purpose of this announcement?

To notify the team that CPR has ended
To indicate that a shock will definitely be delivered
To prepare the patient for transfer
To confirm that no one is touching the patient, bed, or attached equipment during rhythm analysis or shock delivery

5

An AED reports poor electrode contact shortly after the pads have been applied. What is the most appropriate initial response?

Check that the pads are firmly attached to dry skin and confirm the electrode cable is securely connected
Remove the AED and continue CPR without it
Deliver a shock immediately despite the warning
Replace the battery before reassessing the pads

6

A patient achieves return of spontaneous circulation (ROSC) following defibrillation. Why should the AED pads generally remain attached?

They improve routine ECG monitoring
The patient may develop another shockable rhythm requiring rapid reassessment or defibrillation
They prevent skin irritation after defibrillation
They cannot be removed until the AED battery is replaced

7

Which statement best describes closed-loop communication during resuscitation?

Multiple team members perform the same task to ensure nothing is missed
The team leader performs all critical interventions personally
Instructions are given only after each rhythm analysis is complete
Team members repeat instructions to confirm they were heard, understood, and accepted before carrying them out

8

After the patient has been stabilized, which assessment is specifically related to AED use?

Assess for abdominal tenderness
Remove the pads immediately without inspecting the skin
Inspect the skin beneath the pads for erythema, burns, blistering, or other pad-related injury
Repeat rhythm analysis before removing the pads

9

Which information is most important to include when handing over care after a perioperative cardiac arrest?

The sequence of the resuscitation, including CPR initiation, AED use, shocks delivered, patient response, and treatments provided
The brand and model of the AED
The names of every clinician who participated
The estimated cost of the consumables used

10

In a facility with limited resources and only one immediately available AED, which preparation best improves readiness for future emergencies?

Store the AED immediately after use without checking it
Replace the battery only if it no longer powers on
Wait until the next emergency before replacing used pads
Clean the AED, replace used consumables, verify battery status, confirm successful self-testing, and ensure responsibility for device readiness is clearly assigned

Return to main

Page data
Part of Automated External Defibrillation - ECSACONM
Keywords surgery, health
SDG SDG03 Good health and well-being
Authors Ian-laurel
License CC-BY-SA-4.0
Organizations ECSACONM, SELF
Language English (en)
Related 0 subpages, 1 pages link here
Views 3 page views (analytics)
Created July 30, 2026 by Ian-laurel-1
Last edit July 30, 2026 by StandardWikitext bot
Cookies help us deliver our services. By using our services, you agree to our use of cookies.