Use the quiz below to check your understanding of the material.

Instructions

Work through each question carefully to choose the best answer, and submit the quiz to view your results. After completing the quiz, read through the answer explanations to review the reasoning behind both correct and incorrect options.

Return to main

1

During surgery, the ECG shows ventricular fibrillation, but the arterial line waveform is absent and end-tidal CO₂ has suddenly dropped. What should the team do?

Rush the patient out of the OR and into the ICU to begin safe resuscitation
Ask anesthesia to repeat the ECG tracing before responding
Confirm ventricular fibrillation using another monitor before intervening
Begin CPR and activate the emergency response while preparing the AED

2

While the AED is being prepared, the surgical field remains open and the team is unsure who should continue compressions. What is the best response?

Pause compressions until the AED pads are fully applied
Assign a compressor immediately and continue CPR with minimal interruption
Ask the surgeon to decide whether CPR should continue
Wait for the AED prompt before assigning CPR duties

3

Which situation requires an alternative anterior-posterior pad configuration?

The patient has excessive chest hair
The patient has an implanted pacemaker
The left lateral pad site is blocked by the sterile field
The patient is receiving supplemental oxygen

4

During rhythm analysis, the AED operator announces, "Clear." What is the primary purpose of this announcement?

To notify the team that CPR has ended
To indicate that a shock will definitely be delivered
To prepare the patient for transfer
To confirm that no one is touching the patient, bed, or attached equipment during rhythm analysis or shock delivery

5

An AED reports poor electrode contact shortly after the pads have been applied. What is the most appropriate initial response?

Check that the pads are firmly attached to dry skin and confirm the electrode cable is securely connected
Remove the AED and continue CPR without it
Deliver a shock immediately despite the warning
Replace the battery before reassessing the pads

6

A patient achieves return of spontaneous circulation (ROSC) following defibrillation. Why should the AED pads generally remain attached?

They improve routine ECG monitoring
The patient may develop another shockable rhythm requiring rapid reassessment or defibrillation
They prevent skin irritation after defibrillation
They cannot be removed until the AED battery is replaced

7

Which statement best describes closed-loop communication during resuscitation?

Multiple team members perform the same task to ensure nothing is missed
The team leader performs all critical interventions personally
Instructions are given only after each rhythm analysis is complete
Team members repeat instructions to confirm they were heard, understood, and accepted before carrying them out

8

After the patient has been stabilized, which assessment is specifically related to AED use?

Assess for abdominal tenderness
Remove the pads immediately without inspecting the skin
Inspect the skin beneath the pads for erythema, burns, blistering, or other pad-related injury
Repeat rhythm analysis before removing the pads

9

Which information is most important to include when handing over care after a perioperative cardiac arrest?

The sequence of the resuscitation, including CPR initiation, AED use, shocks delivered, patient response, and treatments provided
The brand and model of the AED
The names of every clinician who participated
The estimated cost of the consumables used

10

In a facility with limited resources and only one immediately available AED, which preparation best improves readiness for future emergencies?

Store the AED immediately after use without checking it
Replace the battery only if it no longer powers on
Wait until the next emergency before replacing used pads
Clean the AED, replace used consumables, verify battery status, confirm successful self-testing, and ensure responsibility for device readiness is clearly assigned

Return to main

Page data
Part of Automated External Defibrillation - ECSACONM
Keywords surgery, health
SDG SDG03 Good health and well-being
Authors Ian-laurel
License CC-BY-SA-4.0
Organizations ECSACONM, SELF
Language English (en)
Related 0 subpages, 3 pages link here
Views 4 page views (analytics)
Created July 30, 2026 by Ian-laurel-1
Last edit August 24, 2026 by 162.129.250.57
Cookies help us deliver our services. By using our services, you agree to our use of cookies.