Introduction to field mismatch

No two solar panels are identical. Even after going through same manufacturing process, panels made for a specific ratings does not have same specific outputs. There is generally tolerance range of 5%. For example a two panel made for 100W specification can have have two separate ratings of 95W and 105W.

Series mismatch degrades solar cell performance.

Generally while installing a plant this factor is ignored and panels having extreme ends of specification might get connected in series which further leads to degradation. Plant which intended to give a desired output does not perform on its full potential.

Steps for Revival

  • Take initial readings(STC) for the plant.
  • Take Readings(STC) for individual Solar panels from solar analyzers.
  • Extract the data from analyzers and sort the solar panels on the basis of there short circuit current.
  • According to available infrastructure Re-rack solar panels on the basis of their efficiency within previously sorted panels on the basis of similar short circuit currents.
  • Now make Series parallel connections and convert it Total cross tied connection or any suitable configuration.
  • Take new readings(STC) of the plant. Mark the improvements.
Refer for different configurations Changing photovoltaic array interconnections to reduce mismatch losses: a case study