PV economics: Methodology

Levelised Cost of Electricity (LCOE)

Levelised Energy Cost: "Levelized energy cost (LEC, also called Levelized Cost Of Energy or LCOE) is a cost of generating energy (usually electricity) for a particular system. It is an economic assessment of the cost of the energy-generating system including all the costs over its lifetime: initial investment, operations and maintenance, cost of fuel, cost of capital."

Also known as LUEC: Levelized Unit Energy Cost (LUEC)

see also: Cost of Electricity by Source

Calculation Methods

Levelised Cost of Energy
It can be defined in a single formula as:

LEC=∑t=1nIt+Mt+Ft(1+r)t∑t=1nEt(1+r)t

where

This manual is a guide for analyzing the economics of energy efficiency and renewable energy (EE)

PV LCOE Methodology to be used in the project

The LCOE methodology used in this project is adapted from the Branker's paper and LCOE Article.

link to the appropedia internal article on this.

The expressions for LCOE are given as below:

LCOE=∑t=0TIt+Ot+Mt+Ft(1+r)t∑t=0TEt(1+r)t

LCOE=∑t=0TIt+Ot+Mt+Ft(1+r)t∑t=0T(St)(1−d)t(1+r)t

The total cost includes t=0 year since the installation costs during the first year are not discounted and there's no energy that will be lost. The aggregate costs include the initial payments, interests in case of debt financing, operational and maintenance costs. Government mandated incentives will not be considered here but they can also be included in this expression which will reduce the costs.

In the above expression, the energy generated in a given year (Et) is the rated energy output (St) multiplied by the degradation factor(1-d). The degradation factor reduces the energy output over a period of time. T is the life-span of the PV stand-alone system, It is the initial cost that includes installations, construction, and labor costs. Ot is the operation cost during the year t which is any year between 0 and T, Ft is the interest expenditure for the year t, r is the discount rate. The majority of the costs for PV stand-alone residential systems are upfront costs for installations which largely depends on the available financing schemes and the labor costs.

LCOE Calculations for Grid-Based Electricty

The utility structure for grid-based electricity is highly complicated and varies from utility-to-utility in all the states. For this paper, the utility data from four different states with different climatic conditions is collected from the appropriate sources. The LCOE of a grid based system is then calculated based on fixed charges, cost/kwhr, and taxes. The calculations are made using the excel spread-sheets to find the LCOE for grid consumers with different levels of energy consumption as a percentage of state-wide average consumption. The four different states chosen are Michigan, Florida, Arizona, and New York. These four states have same solar flux so it becomes easier to establish reasonable comparisons with the grid based technology. These four states also have very different climatic conditions from one another with Michigan being extremely cold with long winters and Arizona being very hot most part of the year. The LCOE for PV will compared with LCOE of grid with different levels of customers.

Example PV system Design

Simulation Input

The mathematical simulations for the calculations of the PV system's LCOE is performed in SAM tool. The type of simulation procedure used is PVWatts System model for LCOE calculations. The inputs to the model are Latitude of the location, analysis period, inflation rate, real discount rate, sales tax, ITC 30 % fixed, Degradation Rate, $/Wp cost of installation, DC-AC derate factor, tilt angle (latitude), azimuth =180, and nameplate capacity. Any kind of federal and state level incentives are ignored to maintain consistency at each level of simulation and at the same time that leads to close to realistic results.

Catagory Input Variable Source Notes
Climate Weather Condition from the NREL Solar Prospector website or the Energy Plus website Depending on location
Climate Solar Radiation Depending on location
PV System Design Market option Residential
PV System Design Configuration Flat plate
PV System Design Layout number of modules and inverters, array sizing
PV System Design Tracking and orientation Fixed. Tilt depending on latitude
PV System Design Degradation and derating factors Soiling, Pre-inverter Derates, Post-inverter Derates, Ground Reflectance
PV System Design Module Parameters SAM database Maximum power, maximum power voltage, maximum power current, e.g.
PV System Design Inverter Parameters Manufacturer' webpage AC Voltage, Power ACo, Power DCo, PowerSo, e.g.
PV System Performance System Degradation Manufacturer' webpage Compounded annually
Economic Environment Incentives Not considered in this project
Utility Rate Fixed Monthly Charges OpenEI Online Utility Rate Database Depending on utility's policy
Utility Rate Rate Escalation OpenEI Online Utility Rate Database Depending on utility's policy
Utility Rate Flat Rate OpenEI Online Utility Rate Database Depending on utility's policy
Utility Rate Time of Use Rate OpenEI Online Utility Rate Database Depending on utility's policy
Utility Rate Peak Demand Charges OpenEI Online Utility Rate Database Depending on utility's policy
Utility Rate Time of Use Rate OpenEI Online Utility Rate Database Depending on utility's policy
Utility Rate Tiered Rates OpenEI Online Utility Rate Database Depending on utility's policy
PV System Cost Direct Cost Manufacturer' webpage Cost for PV system components, e.g. inverter, module, installation labor
PV System Cost Indirect Cost Land Cost
PV System Cost Indirect Cost Operation and maintenance cost
Financing Analysis Period 25~30 yrs
Financing Inflation Rate
Financing Real Discount Rate
Financing Taxes Federal Tax, State Tax, Sale Tax
Financing Insurance
Financing Residential Loan Parameters
Electrical Load Residential Load Classified

Determination of tilt angle and cost/kW for full battery back-up

Each location has its unique latitude and longitude. Based on the geo-location of the area, the tilt angle for the solar panel will be determined. This tilt angle is an important parameter in the estimation of the size of battery back-up for the PV system. PVSyst tool will be used to verify the mathematically estimated size and cost of the full battery back-up.

Data Sources

Weather Data

Utilities Rates

PV Manufacturers

Software Tool

Outcome of this project

Some of the key outcomes of this project are as follows:

Sensitivity Analysis