(→‎Calculating Wire Sizes: used bullets (*) for formatting and removed the tabs. Please don't use tabs to try to force formatting.)
Line 39: Line 39:


'''Variable Declarations:'''
'''Variable Declarations:'''
 
*''A<sub>n</sub>'': circular mil area
-''A<sub>n</sub>'': circular mil area
*''n'': AWG
*''m'': AWG
-''n'': AWG
*''Conductor resistivity'': constant, 11.2
*''Current'': current through wire in Amps, acquired from table
-''m'': AWG
*''Roundtrip (RT) wire length'': complete length of wire, ft, acquired from table
*''Allowable voltage drop'': voltage drop through wires, V
-''Conductor resistivity'': constant, 11.2
-''Current'': current through wire in Amps, acquired from table
-''Roundtrip (RT) wire length'': complete length of wire, ft, acquired from table
-''Allowable voltage drop'': voltage drop through wires, V


{{How to
{{How to

Revision as of 01:48, 19 January 2020

Introduction

Describe wire length, voltage loss, etc. here.

Tables

The following table shows the American Wire Gauge (AWG) size for several different round trip (RT) wire lengths based on maximum current (A) for a 12V DC system (assuming 3% maximum wire loss):

Table 1. Wire Sizes
RT length 5A 10A 15A 20A 25A 30A 40A 50A
15 ft 16 12 10 10 8 8 6 6
20 ft 14 12 10 8 8 6 6 4
25 ft 14 10 8 8 6 6 4 4
30 ft 12 10 8 6 6 4 4 2
40 ft 12 8 6 6 4 4 2 2
50 ft 10 8 6 4 4 2 2 1
60 ft 10 6 4 4 2 2 1 1/0
70 ft 8 6 4 2 2 2 1/0 2/0
80 ft 8 6 4 2 2 1 1/0 2/0
90 ft 8 4 2 2 1 1/0 2/0 3/0

This table was adapted from Engineering Toolbox [1] .

Calculating Wire Sizes

Assumptions made:

  1. copper wire resistivity = 11.2 [2]
  2. 3% loss from wires
  3. allowable voltage drop = 0.36V
    • 12V system, 3% (0.03) wire loss -> 12V x 0.03 = 0.36V

Variable Declarations:

  • An: circular mil area
  • n: AWG
  • m: AWG
  • Conductor resistivity: constant, 11.2
  • Current: current through wire in Amps, acquired from table
  • Roundtrip (RT) wire length: complete length of wire, ft, acquired from table
  • Allowable voltage drop: voltage drop through wires, V
File:1 wireloss.png
Table 2. Calculating Wire Sizes


See Help:Tables.

Use help:references to see how to use the reference format.[1]

Use Help:Images on how to upload the graph image(s). Please remember to use a very descriptive name for the file.

References