Main page
New page
Upload file
Help
Community portal
Recent changes
Talk
Contributions
Create account
Enable dark mode
Enable read mode
Log in
View history
What links here
Related changes
Page information
Editing
Universal Harness clip-on Design Lit Review
(section)
From Appropedia
Warning!
You are not logged in.
Log in
or
create an account
to have your edits attributed to your username rather than your IP, along with other benefits.
Anti-spam check. Do
not
fill this in!
=== Novel Active Personal Nanoparticle Sampler for the Exposure Assessment of Nanoparticles in Workplaces === Tsai, C.-J., Liu, C.-N., Hung, S.-M., Chen, S.-C., Uang, S.-N., Cheng, Y.-S., Zhou, Y., 2012. Novel Active Personal Nanoparticle Sampler for the Exposure Assessment of Nanoparticles in Workplaces. Environ. Sci. Technol. 46, 4546–4552. https://doi.org/10.1021/es204580f [https://pubs.acs.org/doi/abs/10.1021/es204580f] Abstract A novel active personal nanoparticle sampler (PENS), which enables the collection of both respirable particulate mass (RPM) and nanoparticles (NPs) simultaneously, was developed to meet the critical demand for personal sampling of engineered nanomaterials (ENMs) in workplaces. The PENS consists of a respirable cyclone and a micro-orifice impactor with the cutoff aerodynamic diameter (dpa50) of 4 μm and 100 nm, respectively. The micro-orifice impactor has a fixed micro-orifice plate (137 nozzles of 55 μm in the inner diameter) and a rotating, silicone oil-coated Teflon filter substrate at 1 rpm to achieve a uniform particle deposition and avoid solid particle bounce. A final filter is used after the impactor to collect the NPs. Calibration results show that the dpa50 of the respirable cyclone and the micro-orifice impactor are 3.92 ± 0.22 μm and 101.4 ± 0.1 nm, respectively. The dpa50 at the loaded micro-Al2O3 mass of 0.36–3.18 mg is shifted to 102.9–101.2 nm, respectively, while it is shifted to 98.9–97.8 nm at the loaded nano-TiO2 mass of 0.92–1.78 mg, respectively. That is, the shift of dpa50 due to solid particle loading is small if the PENS is not overloaded. Both NPs and RPM concentrations were found to agree well with those of the IOSH respirable cyclone and MOUDI. By using the present PENS, the collected samples can be further analyzed for chemical species concentrations besides gravimetric analysis to determine the actual exposure concentrations of ENMs in both RPM and NPs fractions in workplaces, which are often influenced by the background or incident pollution sources. Own Comments: * This could be the new kind of personal sampler which could need clip-on
Summary:
Warning!
All contributions to Appropedia are released under the CC-BY-SA-4.0 license unless otherwise noted (see
Appropedia:Copyrights
for details). If you do not want your writing to be edited mercilessly and redistributed at will, then do not submit it here! You are also promising us that you wrote this yourself, or copied it from a public domain or similar free resource.
Do not submit copyrighted material without permission!
Cancel
Editing help
(opens in new window)
This page is a member of 2 hidden categories:
Category:Pages with magic words
Category:Pages with no main image
Cookies help us deliver our services. By using our services, you agree to our use of cookies.
OK
Discussion