== Coast Central Credit Union  ==
== Coast Central Credit Union  ==


The  [http://www.coastccu.org/ Coast Central Credit Union] is a financial institution in Eureka and the surrounding areas. Coast Central Credit Union has 19 ATMS and 11 member service branches throughout Humboldt County, and the Eureka branch worked with Redwood Coast Energy Authority (RCEA) in getting light retrofits for the building which over time have saved money and CO<sub>2</sub> emissions.<ref>http://www.coastccu.org/locator/index.html</ref>  
The  [http://www.coastccu.org/ Coast Central Credit Union] is a financial institution in Eureka and the surrounding with 19 ATMS and 11 member service branches throughout Humboldt County. The Eureka branch worked with Redwood Coast Energy Authority (RCEA) in getting light retrofits for the building, which over time saved money and CO<sub>2</sub> emissions.<ref>http://www.coastccu.org/locator/index.html</ref>  


[[Image:1118092239.jpg|thumb|right|Eureka Branch|300px]]
[[Image:1118092239.jpg|thumb|right|Eureka Branch|300px]]
Line 11: Line 11:
== Redwood Coast Energy Authority  ==
== Redwood Coast Energy Authority  ==


The Redwood Coast Energy Authority's mission statement says: "The Redwood Coast Energy Authority’s ([http://www.redwoodenergy.org/index.asp RCEA]) purpose is to develop and implement sustainable energy initiatives that reduce energy demand, increase energy efficiency, and advance the use of clean resources available in the region" from the RCEA web page. All of RCEA’s funding comes from contracts and grants, bringing resources to Humboldt County that would not otherwise be available.&nbsp; The RCEA currently has projects to retrofit local businesses' office lighting in Northern Humboldt county and in April 2008 worked with the Coast Central Credit Union '''(CT5 Talk about the retrofit and objective rather than the business or RCEA)'''.<ref>http://www.redwoodenergy.org/ContentPage.asp?ContentID=92</ref>  
The Redwood Coast Energy Authority's mission statement taken from their webpage says: "The Redwood Coast Energy Authority’s ([http://www.redwoodenergy.org/index.asp RCEA]) purpose is to develop and implement sustainable energy initiatives that reduce energy demand, increase energy efficiency, and advance the use of clean resources available in the region". The RCEA currently has projects to reduce local businesses' energy consumption in Northern Humboldt County. In April 2008 RCEA worked with the Coast Central Credit Union and replaced 31 fluorescent bulbs in the Eureka branch.<ref>http://www.redwoodenergy.org/ContentPage.asp?ContentID=92</ref>  


== The Retrofit  ==
== The Retrofit  ==


In April 2008 the RCEA retrofitted the Coast Central Credit Union's (CCCU) office space lighting and replaced the existing lights with brighter and more energy efficient light fixtures in the office.'''(CT6 Explain the lighting and which kind in greater detail)'''
In April 2008 the RCEA retrofitted the Coast Central Credit Union's (CCCU) office space lighting. RCEA replaced the existing lights with brighter and more energy efficient light fixtures in the office. The RCEA replaced 31 T12 light bulbs with 31 T8 lights- 26 in the main lobby and 5 in office spaces. Four of the T12s in the lobby were eight foot bulbs which were replaced with eight foot T8s. Three HL port flood lamps were replaced with three 19 watt Compact Fluorescent Light Bulbs [[CFL|(CFL)]].
 
The Coast Central Credit Union moved to make the light upgrade after RCEA proposed the idea to Bob Boyd, the accounting manager for Coast Central Credit Union. A pushing factor for the retrofit was "primarily cost savings over time, the environment was a secondary benefit," says Boyd. He adds that they "probably would not have made the upgrade without RCEA's assistance. They made me aware of the savings and issues that the lights help". The Coast Central Credit Union has plans to work with RCEA in the future to retrofit another branch, says Boyd.


==== Costs  ====
==== Costs  ====


The installation '''cost''' for the light upgrade made by RCEA was $2,176.19. Coast Central Credit Union was given an energy saving rebate of $919.86 from RCEA, the Coast Central Credit Union ended '''paying''' $1,256.33 for the retrofit.  
The installation '''cost''' for the light upgrade made by RCEA was $2,176.19. The Coast Central Credit Union was given an energy saving rebate of $919.86 from RCEA, the Coast Central Credit Union ended '''paying''' $1,256.33 for the retrofit.


==== Estimated Savings from the Retrofits  ====
==== Estimated Savings from the Retrofits  ====
Line 26: Line 28:


*They would '''save''' $797.70 per year  
*They would '''save''' $797.70 per year  
*Their CO<sub>2</sub> emissions '''reduced''' by 2,487 lbs/year  
*Their CO<sub>2</sub> emissions would be '''reduced''' by 2,487 lbs/year  
*They would '''reduce energy use''' by 4,784 kWh/year  
*They would '''reduce energy use''' by 4,784 kWh/year  
*They would '''reduce power use''' by 1.854 kW
*They would '''reduce power use''' by 1.854 kW
Line 32: Line 34:
== Retrofit Outcomes  ==
== Retrofit Outcomes  ==


The retrofitted office had According to the site manager Gerry Davis "The retrofit was a great success! The new lights are wonderful, now it is always bright enough in the office." '''(W10 Make topic sentence!)''' At the office they are pleased with the new lights because the older lights that they had been using "were not bright enough at times" and now they can always "easily work under bright new lights" commented Gerry Davis. Light use habits did not change after the retrofit, lights are turned on from 9-5 and during that time they are more content with the lights than prior to the retrofit.  
According to the site manager, Gerry Davis, after the retrofit the light quality has improved in the lobby and office spaces. "The retrofit was a great success! The new lights are wonderful, now it is always bright enough in the office" commented Davis. At the office they are pleased with the new lights because the older lights they had been using "were not bright enough at times" and now they can always "easily work under bright new lights," says Gerry Davis. Light use habits did not change after the retrofit was made. The lights are turned on from 9-5 and during that time the employees are more content with the lights than prior to the retrofit.  
   
   
==== Look at the difference ====
==== Look at the Difference ====


In the year before RCEA's retrofit the average energy used by the coast central credit union was about '''2800''' kWh(kiloWatt hours) each month. Over the months since the retrofit the energy consumption at the office has steadily decreased to '''1360''' kWh, as shown in Figure 1, and as a result the CCCU saved $191 from last August's energy bill. '''(''' '''C2''' '''This paragraph is not describing the table to right).'''<br>
In the year before RCEA's retrofit, the average energy used by the Coast Central Credit Union was about '''2,800''' kWh(kiloWatt hours) each month. Over the months since the retrofit, the energy consumption at the office has steadily decreased to '''1,360''' kWh, as shown in Figure 1, and as a result the Coast Central Credit Union saved $191 from last August's energy bill.<br>


== Actual Savings from the Retrofits  ==
== Actual Savings from the Retrofits  ==
Line 43: Line 45:
Table 1 shows the results a year after the lighting retrofit.  
Table 1 shows the results a year after the lighting retrofit.  


{| border="1" cellspacing="0" cellpadding="2" align="right" |
{| border="1" cellspacing="0" cellpadding="2" align="left" |
! Table 1
! colspan="3" | Table 1
|-
|-
! Savings !! Estimated !! Actual !!
! Savings !! Estimated !! Actual
|-
|-
| Energy || 4,784 kWh/year || 8,200 kWh/year
| Energy || 4,784 kWh/year || 8,200 kWh/year
Line 57: Line 59:
==== Energy  ====
==== Energy  ====


The total energy used from April 2007 to April 2008 was 37,150 kWh. The energy used in a year after the retrofit was 28,960 KWh. The difference of the two gave the total energy saved of '''8,200 kWh'''. This value is higher than the wattage reduction estimated by the RCEA, 4,784 KWh to be saved.  
The total energy used from April 2007 to April 2008 was 37,150 kWh. The energy used in a year after the retrofit was 28,960 kWh. The difference of the two gave the total energy saved of '''8,200 kWh'''. This value is higher than the wattage reduction estimated by the RCEA, 4,784 kWh to be saved.


==== CO<sub>2</sub> saved  ====
==== CO<sub>2</sub> saved  ====


The RCEA states the carbon dioxide to energy ratio is 0.519 lbs CO<sub>2</sub> per KWh. Multiplying 0.519 lbs CO<sub>2</sub> per KWh with the total energy used (8,200KWh) produces the reduction in pounds of CO<sub>2</sub> which is '''4,255 pounds of CO<sub>2</sub>'''.
The RCEA states the carbon dioxide to energy ratio is 0.519 lbs CO<sub>2</sub> per kWh. Multiplying 0.519 lbs CO<sub>2</sub> per kWh with the total energy used (8,200KWh) produces the reduction in pounds of CO<sub>2</sub> which is '''4,255 pounds of CO<sub>2</sub>'''.


==== Money saved  ====
==== Money saved  ====


Using the RCEA's average price per kWh of $0.17 and multiplying it to the amount of kWh saved is '''$1,367/year''' and $114 a month, which is a greater savings from the projected RCEA estimates. At this rate of saving it will only take 11 months for the Coast Central Credit Union to make back the money invested into new light fixtures. (Total cost of the retrofit/monthly savings=Time to break even~$1,256.33/$114/month=11 months)  
Using the RCEA's average price per kWh of $0.17 and multiplying it to the amount of kWh, Coast Central Credit Union saved '''$1,367/year''' and $114 a month, which is a greater savings from the projected RCEA estimates. At this rate of saving it will only take 11 months for the Coast Central Credit Union to make back the money invested into new light fixtures. (Total cost of the retrofit/monthly savings=Time to break even~$1,256.33/$114/month=11 months)  


<br>  
<br>  


[[Image:RCEA audit KWH graph.jpg|thumb|left|450px]]
[[Image:RCEA audit KWH graph.jpg|thumb|left|450px|Figure 1]]
 
==Additional Information==
If you would like to learn more about Compact Fluorescent Lightbulbs: [http://www.energystar.gov/index.cfm?c=cfls.pr_cfls EnergyStar.gov]


== References  ==
== References  ==
Line 75: Line 80:
<references />  
<references />  


== Links  ==
[[Image:RCEA.gif|350px]]
[http://www.redwoodenergy.org/ Redwood Coast Energy Authority]
[[Image:Union2.jpg|200px]] [http://www.coastccu.org/ Coast Central Credit Union]


[[Category:Engr115_Intro_to_Engineering]] [[Category:RCEA_energy_audit_reviews]]
[[Category:Engr115_Intro_to_Engineering]] [[Category:RCEA_energy_audit_reviews]]

Revision as of 04:11, 6 July 2010


Coast Central Credit Union

The Coast Central Credit Union is a financial institution in Eureka and the surrounding with 19 ATMS and 11 member service branches throughout Humboldt County. The Eureka branch worked with Redwood Coast Energy Authority (RCEA) in getting light retrofits for the building, which over time saved money and CO2 emissions.[1]

Eureka Branch

Redwood Coast Energy Authority

The Redwood Coast Energy Authority's mission statement taken from their webpage says: "The Redwood Coast Energy Authority’s (RCEA) purpose is to develop and implement sustainable energy initiatives that reduce energy demand, increase energy efficiency, and advance the use of clean resources available in the region". The RCEA currently has projects to reduce local businesses' energy consumption in Northern Humboldt County. In April 2008 RCEA worked with the Coast Central Credit Union and replaced 31 fluorescent bulbs in the Eureka branch.[2]

The Retrofit

In April 2008 the RCEA retrofitted the Coast Central Credit Union's (CCCU) office space lighting. RCEA replaced the existing lights with brighter and more energy efficient light fixtures in the office. The RCEA replaced 31 T12 light bulbs with 31 T8 lights- 26 in the main lobby and 5 in office spaces. Four of the T12s in the lobby were eight foot bulbs which were replaced with eight foot T8s. Three HL port flood lamps were replaced with three 19 watt Compact Fluorescent Light Bulbs (CFL).

The Coast Central Credit Union moved to make the light upgrade after RCEA proposed the idea to Bob Boyd, the accounting manager for Coast Central Credit Union. A pushing factor for the retrofit was "primarily cost savings over time, the environment was a secondary benefit," says Boyd. He adds that they "probably would not have made the upgrade without RCEA's assistance. They made me aware of the savings and issues that the lights help". The Coast Central Credit Union has plans to work with RCEA in the future to retrofit another branch, says Boyd.

Costs

The installation cost for the light upgrade made by RCEA was $2,176.19. The Coast Central Credit Union was given an energy saving rebate of $919.86 from RCEA, the Coast Central Credit Union ended paying $1,256.33 for the retrofit.

Estimated Savings from the Retrofits

The RCEA estimated that the Coast Central Credit Union would benefit in the following ways:

  • They would save $797.70 per year
  • Their CO2 emissions would be reduced by 2,487 lbs/year
  • They would reduce energy use by 4,784 kWh/year
  • They would reduce power use by 1.854 kW

Retrofit Outcomes

According to the site manager, Gerry Davis, after the retrofit the light quality has improved in the lobby and office spaces. "The retrofit was a great success! The new lights are wonderful, now it is always bright enough in the office" commented Davis. At the office they are pleased with the new lights because the older lights they had been using "were not bright enough at times" and now they can always "easily work under bright new lights," says Gerry Davis. Light use habits did not change after the retrofit was made. The lights are turned on from 9-5 and during that time the employees are more content with the lights than prior to the retrofit.

Look at the Difference

In the year before RCEA's retrofit, the average energy used by the Coast Central Credit Union was about 2,800 kWh(kiloWatt hours) each month. Over the months since the retrofit, the energy consumption at the office has steadily decreased to 1,360 kWh, as shown in Figure 1, and as a result the Coast Central Credit Union saved $191 from last August's energy bill.

Actual Savings from the Retrofits

Table 1 shows the results a year after the lighting retrofit.

Table 1
Savings Estimated Actual
Energy 4,784 kWh/year 8,200 kWh/year
CO2 2,487 lbs/year 4,255 lbs/year
Money $797.70/year $1,367.00/year

Energy

The total energy used from April 2007 to April 2008 was 37,150 kWh. The energy used in a year after the retrofit was 28,960 kWh. The difference of the two gave the total energy saved of 8,200 kWh. This value is higher than the wattage reduction estimated by the RCEA, 4,784 kWh to be saved.

CO2 saved

The RCEA states the carbon dioxide to energy ratio is 0.519 lbs CO2 per kWh. Multiplying 0.519 lbs CO2 per kWh with the total energy used (8,200KWh) produces the reduction in pounds of CO2 which is 4,255 pounds of CO2.

Money saved

Using the RCEA's average price per kWh of $0.17 and multiplying it to the amount of kWh, Coast Central Credit Union saved $1,367/year and $114 a month, which is a greater savings from the projected RCEA estimates. At this rate of saving it will only take 11 months for the Coast Central Credit Union to make back the money invested into new light fixtures. (Total cost of the retrofit/monthly savings=Time to break even~$1,256.33/$114/month=11 months)