mNo edit summary
No edit summary
Line 20: Line 20:
* https://www.agorize.com/en/challenges/code-life-challenge?lang=en
* https://www.agorize.com/en/challenges/code-life-challenge?lang=en


==How many are needed?==
==How Many are Needed?==
See Dave Denkenbergers' spreadsheet
See Dave Denkenbergers' spreadsheet
* https://www.youtube.com/watch?v=jmUMolg-7nA
* https://www.youtube.com/watch?v=jmUMolg-7nA
Line 31: Line 31:
https://www.mdedge.com/rheumatology/article/219591/coronavirus-updates/fda-allow-alternative-respiratory-devices-treat
https://www.mdedge.com/rheumatology/article/219591/coronavirus-updates/fda-allow-alternative-respiratory-devices-treat


== Existing designs ==
== Existing Designs ==
* https://github.com/PubInv/covid19-vent-list -- the list now updated daily
* https://github.com/PubInv/covid19-vent-list -- the list now updated daily


Line 45: Line 45:
* https://simulation.health.ufl.edu/technology-development/open-source-ventilator-project/
* https://simulation.health.ufl.edu/technology-development/open-source-ventilator-project/


==MTU designs==
==MTU Designs==


==Testing procedure==
==Testing Procedures==
* https://www.gov.uk/government/publications/specification-for-ventilators-to-be-used-in-uk-hospitals-during-the-coronavirus-covid-19-outbreak
* https://www.gov.uk/government/publications/specification-for-ventilators-to-be-used-in-uk-hospitals-during-the-coronavirus-covid-19-outbreak
* https://github.com/PubInv/ventmon-ventilator-inline-test-monitor
* https://github.com/PubInv/ventmon-ventilator-inline-test-monitor
* ISO 80601-2-12 https://www.iso.org/standard/72069.html
* ISO 80601-2-12 https://www.iso.org/standard/72069.html
 
* MDSR Minimum Requirements: http://www.mdsr.ecri.org/summary/detail.aspx?doc_id=8305
===MTU Testing Procedure===
* Confirm that the peak inspiratory pressure (PIP), respiratory rate (RR), positive end expiratory pressure (PEEP), inspiratroy:expiratory ration (i:e), and tidal volume (TV) are accurate by using the software package that accompanies the lung.
* Test the alarms by unplugging the machine, wiring, and appropriate tubing. The accessories that should be tested are:
  *'''Low Pressure Alarm:''' Decrease the PIP to an abnormal value.
  *'''High Pressure Alarm:''' Increase the PIP value to an abnormal value.
  *'''Oxygen Concentration Alarm:''' Increase/decrease the percentage of oxygen per breathe to above/below the safety range (19.5-23.5%).
  *'''Battery Backup Alarm:''' Unplug the ventilator's primary battery from the voltage source.
  *'''Wire Disconnection Alarm:''' Unplug a wire while the ventilator is running.
  *'''Oxygen Tube Disconnection Alarm:''' Unplug the oxygen tube from the ventilator while the machine is on.
===Safety Precautions===
* Confirm that the wiring in the ventilator is correctly set-up (see wiring diagram)
* Make sure that the ventilator is properly connected to the artificial lung with the proper adapter size (see picture below)
* Confirm that the artificial lung is set-up correctly BEFORE turning the machine on (see manual below, pg.#)
==See also==
==See also==
* [[Collaborative COVID-19 initiatives]]
* [[Collaborative COVID-19 initiatives]]


[[category:MOST methods]]
[[category:MOST methods]]

Revision as of 18:18, 1 April 2020

Over the rest of the semester MOST and well as the MTU Open Source Hardware Enterprise will be documenting, building and testing open source ventilators. If you want to help please do.

Background

Follow literature review protocols from the group here:[1]

How Many are Needed?

See Dave Denkenbergers' spreadsheet

https://www.mdedge.com/rheumatology/article/219591/coronavirus-updates/fda-allow-alternative-respiratory-devices-treat

Existing Designs

MTU Designs

Testing Procedures

MTU Testing Procedure

  • Confirm that the peak inspiratory pressure (PIP), respiratory rate (RR), positive end expiratory pressure (PEEP), inspiratroy:expiratory ration (i:e), and tidal volume (TV) are accurate by using the software package that accompanies the lung.
  • Test the alarms by unplugging the machine, wiring, and appropriate tubing. The accessories that should be tested are:
 *Low Pressure Alarm: Decrease the PIP to an abnormal value.
 *High Pressure Alarm: Increase the PIP value to an abnormal value.
 *Oxygen Concentration Alarm: Increase/decrease the percentage of oxygen per breathe to above/below the safety range (19.5-23.5%). 
 *Battery Backup Alarm: Unplug the ventilator's primary battery from the voltage source.
 *Wire Disconnection Alarm: Unplug a wire while the ventilator is running. 
 *Oxygen Tube Disconnection Alarm: Unplug the oxygen tube from the ventilator while the machine is on.

Safety Precautions

  • Confirm that the wiring in the ventilator is correctly set-up (see wiring diagram)
  • Make sure that the ventilator is properly connected to the artificial lung with the proper adapter size (see picture below)
  • Confirm that the artificial lung is set-up correctly BEFORE turning the machine on (see manual below, pg.#)

See also