Line 6: Line 6:
**Use chopper to measure ac instead of dc, claim order of magnitude better long-term stability from it.
**Use chopper to measure ac instead of dc, claim order of magnitude better long-term stability from it.
**Much improvement from simultaneous reference and measurement beam.
**Much improvement from simultaneous reference and measurement beam.
*[http://rsi.aip.org/resource/1/rsinak/v13/i5/p229_s1 A Turbidity Comparator]
**Article from 1942; old aparatus, old electronics setup; not really useful.
*[http://rsi.aip.org/resource/1/rsinak/v28/i2/p129_s1 Comparison Type Nephelometer]
**Measure transmitted and scattered light with an integrating sphere each, and direct intensity, all three at once.
**Polarized, old style (1952), not really useful.
*[http://proceedings.aip.org/resource/2/apcpcs/914/1/419_1 Development of a Precise and in Situ Turbidity Measurement System]
**Can't get the article so far.
*[http://www.sciencedirect.com/science/article/pii/S0038092X0600291X Direct and indirect determination of the Linke turbidity coefficient]
**Not relevant for us; it's about air turbidity.
*[http://jcp.aip.org/resource/1/jcpsa6/v19/i6/p803_s3 Expressions for Turbidities]
**Note how to compute turbidity with only tabulated functions.  Irrelevant now we have computers.
*[http://jcp.aip.org/resource/1/jcpsa6/v65/i7/p2913_s1 Inverted turbidity versus concentration dependence for aqueous polynucleotide–protein mixtures: Visible turbidity at low concentrations]
**Not about measurement method.
*[http://rsi.aip.org/resource/1/rsinak/v48/i5/p528_s1 LED marine beam transmittance meter]
**Comparable to our stuff, but analog.
**2% accuracy claimed.
*[http://jcp.aip.org/resource/1/jcpsa6/v22/i1/p147_s1 Light Scattering Determination of the Absolute Turbidity of Water]
**

Revision as of 20:52, 4 June 2013

  • A computercontrolled turbidity apparatus
    • I_t = I_0e^{-(α+τ)l}
    • We're looking for τ.
    • Aparatus for measuring turbidity as function of temperature; includes oven to place sample in. Claims 0.001/mm accuracy and 0.5% precision.
    • They measure transmitted light and assume no absorbtion; use a laser of polarized light with beam splitter.
    • Use chopper to measure ac instead of dc, claim order of magnitude better long-term stability from it.
    • Much improvement from simultaneous reference and measurement beam.
  • Comparison Type Nephelometer
    • Measure transmitted and scattered light with an integrating sphere each, and direct intensity, all three at once.
    • Polarized, old style (1952), not really useful.