(Created page with "{{MOST}} <!-- Comments that appear only in the edit view are formatted like this. --> <!-- These comments are offered as an aid as you get started. Remove as you wish. --> <!...")
 
No edit summary
Line 15: Line 15:
*small particle size of glass powder poses a health hazard-- operate in fume hood if possible, wear safety glasses and respirator.
*small particle size of glass powder poses a health hazard-- operate in fume hood if possible, wear safety glasses and respirator.
==Equipment or Bill of Materials==
==Equipment or Bill of Materials==
 
MG200 recycled soda-lime glass powder, by Vitro Minerals
crushed polypropylene
 
==Calibration & Tolerances==
==Calibration & Tolerances==
 
*zero balance w/ empty container before each measurement
*tolerance of MyWeigh iM01 balance is 1000+/- 0.01 grams
*sample mass should fall within a tolerance of +/- 0.1g, preferrably within 0.01 or 0.02 for more precision
==Operation & Procedure==
==Operation & Procedure==
# prepare sample compositions, starting with 100% polypropylene and increasing glass content in increments of 10% by weight, measured on a balance with tolerance of +/- 0.1g
# prepare sample compositions, starting with 100% polypropylene and increasing glass content in increments of 10% by weight, measured on a MyWeigh iM01 balance
# store measured glass for each composition in a plastic container with closed lid
#
# store measured glass for each composition in a correctly labeled plastic container with closed lid
*if containers of proper size are in short supply, use multiple smaller containers and label correctly
# email Dr. Paul Fraley (pdfraley@mtu.edu)
# email Dr. Paul Fraley (pdfraley@mtu.edu)
# take this safety training:
# take this safety training:

Revision as of 16:34, 24 November 2018

Sample photo caption.
You can put an abstract (a brief description of your method) here and the text you would copy into an article.

Introduction

polymer and glass have very different particle sizes (glass powder <44 micron, polymer ~5mm diameter) these particles will not mix evenly unless the polymer melts

Safety

  • small particle size of glass powder poses a health hazard-- operate in fume hood if possible, wear safety glasses and respirator.

Equipment or Bill of Materials

MG200 recycled soda-lime glass powder, by Vitro Minerals crushed polypropylene

Calibration & Tolerances

  • zero balance w/ empty container before each measurement
  • tolerance of MyWeigh iM01 balance is 1000+/- 0.01 grams
  • sample mass should fall within a tolerance of +/- 0.1g, preferrably within 0.01 or 0.02 for more precision

Operation & Procedure

  1. prepare sample compositions, starting with 100% polypropylene and increasing glass content in increments of 10% by weight, measured on a MyWeigh iM01 balance
  2. store measured glass for each composition in a correctly labeled plastic container with closed lid
  • if containers of proper size are in short supply, use multiple smaller containers and label correctly
  1. email Dr. Paul Fraley (pdfraley@mtu.edu)
  2. take this safety training:

Shutdown

References