Introduction

In many developing countries, there is an increasing need for affordable water gathering systems. The main system currently used in several developing countries is a hand-operated pump since they are the most sustainable low cost option for safe water supply in resource poor settings. They are used for many purposes, industrial, marine, irrigation, and leisure activities.

The hand pump being analyzed in this report is very cheap and easy to make, it can be seen in figure 1 below. It utilizes the water hammer effect to pump water. The water hammer effect is a pressure surge or wave resulting when fluid in motion is forced to stop or change direction suddenly. Water hammer commonly occurs when a valve is closed suddenly at an end of a pipeline system, and a pressure wave propagates in the pipe.[1]

Hand Pump

Figure 1: Hand Pump

Engineering

Functionality

A diagram of the system can be seen in figure 2 below. When the hose moves down, the foot valve on the end of the garden hose opens allowing the flow of water. When the garden hose moves up, the foot valve on the garden hose closes and more water is pulled into the PVC schedule 40 pipe.

Function of the Hand Pump

Figure 2: Function of the hand pump

Calculations

As mentioned earlier this pump utilizes the water hammer effect. In most practical cases, this effect occurs at very high flow rates and pressures so compressibility of the fluid should be considered. For the hand pump, being created incompressibility can be assumed because such low flow rates and pressures are being considered are too low for compressibility to occur.

The density of water at atmospheric conditions is ρ=1000kg/m3. This factor can be used in the calculation of the pressure of the water entering the foot valve at the end of the hose. The pressure of the water entering at the end of the hose, P1, can be found using equation (1).

Equation 1

Where the gravitational constant is g=9.81m/s2 and the atmospheric pressure is 101325Pa. The velocity of the water entering the pump will be the same as the velocity at which the user propels the hose downward into the well. Assuming in each downward motion the hose travels a distance of 0.15m and this motion takes 0.5 seconds to execute than the velocity at which the hose is moving is 0.3m/s. Therefore the velocity of the water entering the hose is V1=0.6m/s. Since compressibility effects can be ignored the Bernoulli equation, equation (2), can be used to calculate the exiting velocity.

Equation 2

Where h2-h1 is the difference in height between the top and bottom of the hose and this is indicated in figure 3 below. P2 can be taken as zero since it is equal to the atmospheric pressure. Note a control volume was taken around the hose and this is indicated in figure 3 below.

Demonstration of Flow

Figure 3: Demonstration of flow

Using the exiting velocity, V2, the volumetric flow rate of the system can be found with equation (3).

Equation 3

Where Equation 4

Flow rate for different well lengths can be seen in table 1 below.

Table 1: Flow rates for different well lengths

Well Depth (m) 10 20 50 100 150
Density of Water (kg/m^3) 1000 1000 1000 1000 1000
Gravity (m/s^2) 9.81 9.81 9.81 9.81 9.81
Atmospheric Pressure (Pa) 101325 101325 101325 101325 101325
Pressure at Intake (Pa) 199425 297525 591825 1082325 1572825
Exiting Velocity (m/s) 9.93 14.03 22.18 31.36 38.40
Exiting Area (m^2) 0.000198 0.000198 0.000198 0.000198 0.000198
Volumetric Flow Rate (m^3/s) 0.002 0.003 0.004 0.006 0.008

Regional Considerations

Community participation in rural water supply is essential for the success of the implementation of hand-powered pumps. As the number of hand pumps installed in a country increases the demand for mobile maintenance teams increases also, unless the village assumes responsibility for the maintenance of the hand pump. For this to occur the hand pump technology has to be suitable for village maintenance, there has to a designated and trained caretaker of the pump and there must be spare parts that are readily available. To purchase spare parts the village can set up a cash collection fund and possibly receive backup from the government or other local agencies. [2]

Plastic materials are increasingly used in hand pump designs because of low costs and corrosion resistance. However, manufacturing processes to make high quality plastic products are often lacking in developing countries. [2]

This pump is limited to regions with wells that have deep water levels to allow for the pumping action. Water quality plays an important role in water supply from wells. Problems that are frequently encountered are corrosivity (affecting the pump parts and the rising main if made of iron), excess minerals (possibly resulting in a taste that is objectionable to the users), and surface pollution (i.e. organic materials or agriculture chemicals). Where such problems are suspected to exist, the water quality should be appropriately monitored and the design and completion of the wells corrected to avoid problems to the degree possible. [2]

Required Materials

Here is a list of the required materials needed to build this pump:

1. 5/8” or larger garden hose (inside diameter)

Garden Hose

2. 3/4" garden hose adapter

Adapter

3. Open eye-hook, washers and nuts

Open Eye-hook

4. 1/2" nylon cord

Nylon Cord

5. 1/2" carriage bolts, washer and nuts

Carriage Bolts

6. 2” inside diameter PVC schedule 40 pipe

PVC Schedule 40 Pipe

7. 1/2" holes in 2” PVC pipe sleeve

8. 3/4" foot valve

Foot Valve

9. 2” PVC schedule 40 pipe cap

PVC Schedule 40 Pipe Cap

If these materials are not available, the following alternative materials can be used:

1. Instead of a garden hose any hose of similar size can be used

2. Instead of an adapter any other method for attaching the foot valve to the hose can be used as long as an appropriate seal is made between the two

3. Any other hook can be used as opposed to the open eye hook

4. Instead of the nylon cord any other rope could be used

5. Any other bolts could be used instead of carriage bolts

6. Any other 2” pipe could be used instead of the PVC schedule 40 pipe

7. Any other pipe cap could be used as long as it fits the appropriate pipe being used

Required Tools

Here is a list of the required tools needed to build the pump:

1. Drill and drill bits

2. Pipe tape or compound to provide tight seal

3. PVC solvent or glue to attach pipe cap

Alternative tools:

1. Any other device that can drill the appropriate size holes could be used

2. Any other sealing glues or solvents could be used to match the appropriate hose and pipe used

3. Any other methods could be used to attach the matching cap with the appropriate pipe used in the assembly of this pump

Hand Pump Design

Suggested Design

Below is a systematic process showing how to build the pump.

Step 1 – Glue the 2” PVC schedule 40-pipe cap onto the end of the 2” PVC schedule 40 pipe and let dry

PVC Glue

Step 2 – Drill twelve 1/2" holes in PVC pipe with 1” spacing

Drill

Note drill holes where arrows are located

Step 3 – Fasten PVC schedule 40 pipe to the side of the well casing with 1/2" carriage bolts and nuts

Bolts

Step 4 – Fasten the open eye-hook to the side of the well wall with the washers and nuts

Eye-Hook

Step 5 – Thread the garden hose on to the 3/4" garden hose adapter

Thread Adapter

Step 6 – Thread the 3/4" foot valve onto the 3/4” adapter and garden hose

Thread Foot Valve

Step 7 – Tie the 1/2" nylon rope around the other end of the garden hose

Nylon Rope1

Step 8 – Tie a loop on the other end of the 1/2" nylon rope

Loop

Step 9 – Feed the garden hose down the PVC schedule 40 pipe with the 3/4" foot valve first

Feed

Step 10 – Hook the nylon rope onto the open eyehook to secure the hose to the side of the well wall

secure

Prototype

To test the validity of this pump a prototype was created. The materials used include:

1. 1/2" rubber hose with a length of 52”

Prototype Rubber Hose

2. 2” PVC schedule 40 pipe with a length of 60”

Prototype PVC Schedule 40 Pipe

3. 3/4" foot valve

File:Pfootvalve.jpg

4. 3/4" adapter

File:Padapter.jpg

The assembled prototype of the pump can be seen in figure 4 below.

Figure 4: Assembled prototype in water

It is recommended that when using the pump short quick up and down movements are made to pump the water.

Cost Analysis

References

  1. Plast-O-Matic: Valve Info Center, "Water Hammer", http://www.plastomatic.com/water-hammer.html, Accessed March 23, 2010
  2. 2.0 2.1 2.2 Tschannerl, Gerhard., Bryan, Kedar., Rural Water Supply Handpumps Project, The World Bank, 1984, ISBN 0821306480
Cookies help us deliver our services. By using our services, you agree to our use of cookies.