Irrigation Schemes mainly comprise of canal irrigation and lift irrigation schemes. In such schemes, the most important and yet the most neglected portion is distribution of water. Let us first consider lift irrigation schemes

IMPORTANCE OF LIFT IRRIGATION SCHEMES (LIS)

As per the NABARD – National Bank for Agricultural and Rural Development (India) - data, there are 1401 LIS financed by them. The total financial outlay (TFO) is Rs. 6462.5 million . The proposed area under irrigation is 22000 hectare. Out of these LIS, as many as 573 LIS are defunct. The main reason is poor distribution of water. In addition there are LIS which are financed and implemented by government, sugar factories and individual farmers.In case of irrigation schemes, the importance of “Lift Irrigation Schemes” is unique and distinctive. In such schemes, many farmers can come together and implement a large lift irrigation scheme on private or co-operative basis. This way, they get certain benefits of large schemes. Such large lift irrigation schemes comprise of two main parts.
1. To carry water by means of pumps from the source of water to the main delivery chamber which is situated at the top most point in the command area
2. To distribute this water to the fields of the beneficiary farmers by means of suitable and proper distribution system.

Of these two, the first part is comparatively easy and there are some technical guide lines for its design. If this is properly implemented for selection of pipes (diameter and pressure rating), valves and pump sets, there does not arise any problem in this part. But the second part of distribution is very important and comparatively complicated.
The reasons are:
1. The distribution system totally comprises of gravity pipe lines. The gravity lines are designed totally on the basis of the available head, with out any pumping system. This limits the job of design engineer.
2. The area under the irrigation is scattered with varying topography. Therefore, each gravity pipe line has different available heads and different lengths.
3. The area of individual farmers is different.
4. The design engineer has to select the diameter of pipe from the standard diameters available in the market. The pipe diameter selected is the next higher diameter (than the design diameter) available in market. Higher diameter pipes are used and this affects the discharge through the pipes. The pipe line carrying water to the low level fields carry more water than the similar requirement on the elevated field. The distribution is not proper and dissatisfaction and frustration on the part of farmers leads to indifference and apathy towards the scheme.
5. The distribution system is controlled by valves on the basis of time schedule. The farmers operate the valves to their benefit which results in altercation and quarrels among the farmers.

With all these limitations, there are the following prevailing systems to distribute the water in the command. CONVENTIONAL SYSTEM 2. IRRIGATION SCHEDULE SYSTEM


CONVENTIONAL SYSTEM

In this system, the pipe lines are designed from the Main Delivery Chamber (MDC) to the respective fields a sunder: Thereafter,

  • The area under irrigation is divided in to different blocks according to topography determined by contour plan. The water requirement of individual blocks is determined. Then the pipe lines are designed for these blocks depending on the available head and discharge required.
  • The next available diameter than the design diameter is selected for the pipe line. E.g. if the design diameter is 95 mm, the next higher diameter of 110 mm OD in PVC pipes will be selected and fitted.
  • Field Delivery Chambers are constructed on the distribution pipe lines, and valves are fitted to control the flow of the pipe lines.
  • Water is distributed from the MDC at a time or as per some pre decided time table.
  • The flow is controlled by the valves.
  • In this system the above reasons lead to unequal and disproportionate distribution. The lines for lower fields carry more discharge. The control of valves is misused or is at the mercy of influential farmers.

This way, some farmers get more water and some get less. Some farmers do not get any water at all. The differences amongst them increase. The lack of interest results in non cooperation to run the scheme. This results into shut down of the scheme.

IRRIGATION SCHEDULE SYSTEM

This system is similar to the above. The only difference is that instead of supplying water to all blocks at the same time, the area is divided into three or four equal parts, and each part is given the entire discharge for one day. This means each part gets rotation of the full design discharge on the fourth or fifth day. This system has all the drawbacks of the conventional system. In addition, its another drawback is that the diameters of the distribution pipes increase due to the supply of entire discharge to one third or one fourth area. This leads to the increase in the cost of the scheme which becomes a burden on the beneficiary farmers. Therefore, we have invented and developed a system having principle of equal and/or proportionate distribution. The salient features of this system are:

  • Every farmer gets precisely equal or proportionate water at the same time. For example, if the discharge of the scheme is 100 LPS and 20 members in the scheme, every farmer precisely gets 5 LPS discharge as long as the pump is running. OR
  • Every farmers gets precisely proportionate water to his area under irrigation and investment, at the same time. If the scheme is on the basis of area, and if a farmer has invested for two hectare area, he will precisely get double the water of the farmer investing for one hectare. A farmer investing for six hectare will get three times as much water; and so on. As long as the pump is running, all the farmers will get PROPORTIONATE discharge.
  • There is no scheduling or time table such as so many hours or so many days in a week for farmers or their groups. As per the availability of electricity, as long as the pump is running, all the farmers will get EQUAL or PROPORTIONATE discharge.
  • No need of control valves: Control valves are NOT needed in this system. The problems of malfunctioning of valves and unauthorized operating of the same do not arise. The cost of the valves also saved. The dependability or reliability of the scheme is increased among the farmers.
  • No need of an operator: Since there are no valves, valve operator is not needed, thereby saving the expenses for the same.
  • As the total discharge is delivered at a time, distribution pipe diameter required is less with saving in the cost of the distribution system.
  • Since equal or proportionate distribution is foolproof, certain and doubtless; farmers willingly and happily share the capital expenses (loan and investment) and recurring expenses in that proportion. The repayment of the loan is in time and recurring expenses like electric bill, water charges, maintenance cost are shared in time.

The principle used in this system is very simple and commonly observed. ‘Water maintains its level in a closed container’ is that principle. In main delivery chamber, pipes are fitted at precisely on the same level. The number of pipes depends on the number of farmers or groups. The pipes deliver water in to a distribution tray. They are grouped for further conveyance through a common pipe line. At the further delivery point, the same type of field distribution chamber is constructed, and so on. While designing new schemes, we give water on the basis of units rather than based on crop and area to be irrigated. We therefore decide a unit of water and farmer decides how many units he wants, and shares capital and recurring expenses accordingly. He has then freedom to take any crop and to irrigate any amount of area by using water saving techniques like micro irrigation and mulching etc.

APPLICATIONS:

  • For the new irrigation schemes
  • For the rehabilitation of the schemes which are closed up due to improper distribution, thereby reutilizing the vast amount of funds blocked in these schemes.
  • Applicable to any size of scheme from two farmers to thousands of farmers or from a few hectares to thousands of hectares.

APPLICATION TO CANAL DISTRIBUTION SYSTEM

This type of distribution system is applicable for distribution from canals also. From all the dams, irrigation water is distributed through canals and distributaries. There are many water distribution co-op. societies on these canals. Since the key point in equal and proportionate distribution is the delivery chamber, it can be used in canal systems also with equal effect. The farmers at the tail point will also get their share of water without any doubt. And all the benefits described above can be reaped by the member farmers. We have successfully implemented many small and large LIS in this way. The satisfaction level of the beneficiary farmers is very high.


COMPARATIVE CHART

Conventional System Equal and Proportionate System
Water is distributed in unequal quantity, either more or less than design,
depending on the available gravity and diameter of the pipe line
Every farmer gets PRECISELY equal or proportionate water at the same time
Valves are needed. There arise differences on operation of valves.
Expenses for valves, their operation and maintenance are additional
Valves are not needed. Expenses towards the same are saved.
There is no question of differences
There is scheduling or time table for distribution.
This time table is disturbed when the pumps do not run due to power failure or maintenance.
There is no scheduling or time table.
All farmers get their precise share of water as long as the pumps are running
The cost of the scheme is comparatively more The cost of the scheme is comparatively less
The share of investment is not equal or proportionate.
Individual loan account cannot be maintained. Insincerity towards loan repayment increases
The share of investment is equal or proportionate.
Individual loan account can be maintained. Loan repayment is proper and in time
Planning is based on area or crop which leads to complications. Planning based on UNITS of water.
The farmer has freedom to take any crop and irrigate any amount of area


Some Schemes Implemented On Equal Distribution Basis

Name of the Scheme Location Type of Scheme Design Discharge Liters/sec Irrigable Area, Hectare No. of Members Working Since Financed By Estimated Cost, Rs. in lakhs Actual Expenses
Shivganga
Co-op LI Scheme
Pimpalgaon Bahula
Tal Dist Nashik
New Scheme
EQUAL distribution
2500 50 61 1999 Nashik Dist
Central Coop Bank Ltd
45.44 40.00
Jai Malhar
Co-op LI Scheme
Indorey, Tal Dindori
Dist. Nashik
New Scheme
EQUAL distribution
100.00 100 114 2004 Own Funds and
Maharashtra Prabodhan Seva Mandal
75.00 72.30
Karbhari R. Nagre
and Others
Pimpalgaon Bahula
Tal Dist. Nashik
New Scheme
EQUAL distribution
30.00 40 7 2002 Own Funds 44.50 37.00
Waregaon
Pathre Co-op LI Scheme
Pathre, Tal.
Sinnar Dist. Nashik
New Scheme
PROPORTIONATE distribution
200.00 170 163 2006 Nashik District
Central Co-op Bank Ltd
150.00 N.A
Sonai Co-op
LI Scheme
KONDHAR, Tal. Nandgaon
Dist. Nashik
Scheme for Rehabilitation
PROPORTIONATE distribution
Survey , design completed,
proposal submitted
and pending for financial sanction.
Nashik District
Central Co-op Bank Ltd
Loknete V. Hiray
Co-op LI Scheme
Pumbarde tal. Malegaon
Dist Nashik
Scheme for Rehabilitation
PROPORTIONATE distribution
Survey , design completed,
proposal submitted
and pending for financial sanction
Nashik District
Central Co-op Bank Ltd
Yogesh Co-op
LI Scheme
NALWADI, Tal Dindori
Dist. Nashik
Scheme for Rehabilitation
PROPORTIONATE distribution
Survey , design completed,
proposal submitted
and pending for financial sanction
Nashik District
Central Co-op Bank Ltd

Since 2008 till today i.e. 2014, many small groups of farmers have very successfully implemented this concept in Nashik district, and the adjacent Ahmadnagar district. The group ranges from 4 to 20 farmers and area under irrigation from 20 hectares to 60 hectares ( 50 to 150 acres) One more scheme for more than 100 hectares (250 acres )for approximately 100 farmers is being designed by Mr Yashpal Morey in Nashik disrict.


This system has been invented, developed and successfully implemented by MR.Yashpal Morey. He is an Agricultural Engineer and Agro Consultant based in the city of Nashik in India. Mr. Morey has been working on numerous irrigation projects in Maharashtra and India, and his experience of over 30 years helped him to develop this pioneering system. It is needed that more and larger schemes should adopt this concept, and that the concept should be used by irrigation departments for distribution of water through canals

Award Winning Concept

An article on this concept received an award in Maharashtra Sinchan Parishad (Irrigation Convention) 2008 held in April 2008.


© Yashpal Morey, Agril. Engineer and Agro Consultant. Eastern Star Consulting Engineers Nashik 422 101 India

Cookies help us deliver our services. By using our services, you agree to our use of cookies.