No edit summary
(45 intermediate revisions by 11 users not shown)
Line 1: Line 1:
{{Copyedit}}
=Disadvantages Kerosene lamps=


=Why=
*Kerosene lamps pollute the air, which can lead to health problems


{{Wikipedia p|Cold cathode}}
*Kerosene lamps lose a lot of energy while producing heat


Kerosene lamps pollute the air, which can lead to health problems
=Disadvantages Edison light bulb=


*Glow bulb lamps lose a lot of energy producing heat
*Glow bulb lamps lose a lot of energy while producing heat and attracts insects


*LED lighting is not as energy efficient as fluorescent bulbs and tubes.
=Disadvantages LED lighting=


*Energy saving fluorescent bulb lamps have a short life and cannot handle vibrations and are expense.
*LED lighting is very expensive as an alternative to fluorescent tubing though it does offer an increased lamplife of 50,000 run hours (approx 10 years) over a fluorescent tube which is typically 9000 hours. Modern LED alternatives to fluorescent tubing also offer a power saving of about 40-60% though this saving is normally not great enough to pay back the difference in cost between the LED alternative and fluorescent tube over the life of the fitting.


*Standard fluorescent tubes have a long life and are energy efficient.
=Disadvantages Energy saving [[fluorescent bulbs]] lamps=


*The ballast of the fluorescent bulbs and tubes have a thyristor in the electronic ballast.
*Energy saving [[fluorescent bulbs]] lamps have a short life and cannot handle vibrations and are expensive
* Many types contains mercury and other dangerous metals


*This thyristor spoils a lot of energy producing heat.
=Advantages Standard fluorescent tubes=


*The outend of the fluorescent lamp have two filamento coils.
*Standard fluorescent tubes have a long life and are energy efficient and are cheap.


*These coils spoil a lot of energy producing heat
=Disadvantages ballast with thyristor=


*Heat attracts and kills insects
*Fluorescent bulbs and tubes have a thyristor in the electronic ballast


*The ballast of a CCFL lamp have two transistors instead of a thyristor
*This thyristor spoils a lot of energy producing heat.


*These transistors do not heat a match up.
*The base or outlet end of the fluorescent lamp has two filament coils


*The CCFL tube lamp haves cold cathodes instead of filamento coils.
*These coils spoil a lot of energy producing heat wen used with a thyristor ballast


*Cold cathodes out ends do not heat up.
=Advantages CCFL and EEFL inverter=


*This makes the CCFL lamp very use full to use in poor areas.
[[Wikipedia:CCFL inverter]]


It is imported to create a lamp cap with the following benefits:
*have no thyristor that heat up, but has two transistors.


-Energy efficient
*CCFL inverter can work on minimum 6 volt power


-Protected against falling from heights
=Advantages CCFL lamp=


-Protected against vibrations.
*Smaller, thinner, and more light weight than a known fluorescent lamp.
-Protected  against impressions.


-Water and incest tight .
*Have no filament coils that heat up, but Cold cathodes.


-Acceptable design.
*Have a longer life


-Easy to adjust in a direction.
*Can better handle vibrations.


-Cheap cost.
*This makes the CCFL lamp very use full to use in [[all]] areas


-Can work on low plus and min (DC) voltage
=Advantages EEFL lamp=


-
*Smaller, thinner and more light weight than a known fluorescent lamp.


-
*Have no filament coils that heat up, but External Electrodes.


-
External Electrodes can easely take lose from the Fluorescent Lamp


*Have  a longer life than CCFL


-
*Can better handle vibrations.


*More EEFL lamps can connect parallel on one EEFL inverter


*This makes the EEFL lamp very use full to use in poor areas


=Advantages CCFL inverter+FL lamp =


*you can use the CCFL inverter to light up a old fluorescent lamp.
*The inverter use the filament coils like Cold cathodes.
*Does not Matter if these coils are broken.
*the end of the fluorescent lamp does not heat up.


=Disadvantages CCFL and EEFL=


The mercury in the tubes [[fluorescent-bulbs]]


==Importance of Lamp Cap with the following benefits:==


[[Image:ccfl in old scanner.GIF|thumb|right|CCFL in old document scanner]]
Like the [[3rd world CCFL lamp (2007 model)]] the inverter near the CCFL-tubes-lamps
 
== CCFL lamp and ballast out of a old document scanner ==
 
A ballast is the same as an Inverter
WARNING the CCFL ballast haves dangerous high voltage output
 
Because the CCFL does not heat up like a TL lamp, the CCFL  uses les energie than the TL lamp.
 
You can use a CCFL and electronic ballast out of a old SCSI document scanner.
 
 
 
Not al scanner have CCFL technology the new one have led technologie and very old black and wite fax have led technology
 
Take off the cover
 
Unscrew the CCFL ballast related electronic print
 
Take careful out the CCFL tube lamp.




-Energy efficient


-Protected against falling from heights


-Protected against vibrations


[[Image:old scanner with ccfl and ballast.jpg|thumb|middel|old scanner with CCFL and ballast]]
-Protected  against impressions


-Water, air and insect tight


-Acceptable design


Make a draw of the electronic scema.
-Easy to adjust in any direction


-Inexpensive


-Can work on low plus and min (DC) voltage


-can be made partly of recycled materials


[[Image:cut off ballast back.jpg|thumb|middel|cut off ballast back]]


Some times you find a print with the CCFL ballast electronic and some scanning electronic.
[[Image:ccfl in old scanner.GIF|thumb|left|CCFL in old document scanner]]


You have to seperate the scanning electronic parts.
== How to==


Cut of the CCFL ballast unrelated electronic.
You can use a CCFL and electronic ballast out of an old SCSI document scanner. Just so you know a ballast is the same as an Inverter. Also not all scanners have CCFL technology the new ones have LED technology and very old black and white faxes have LED technology. You may be lucky enough to find in some scanners a separated CCFL inverter circuit board.


This is the back of the ballast related print part.
WARNING the CCFL inverter has a dangerous high voltage output


[[Image:old scanner with ccfl and ballast.jpg|thumb|right|old scanner with CCFL and inverter]]
Instructions:


*Make a drawing of the electronic schema


[[Image:cut off ballast front.jpg |thumb|middel|cut off ballast front]]
*Some times you can find a circuit board with the CCFL inverter electronics and some scanning electronics.


Cut of the CCFL ballast unrelated electronic.
*You have to separate the scanning electronic parts


This is the front of the ballast related print part.
*Cut of the CCFL ballast unrelated electronic


*Now it have the right shape to use this inverter to light up the CCFL lamp.


*It is possible to use a CCFL inverter in combination with a normal fluorescent tube lamp


[[Image:take out the ccfl and ballast.JPG|thumb|middel|CCFL and ballast|300px]]




Make it 30 mm wide.
[[Image:cut off ballast back.jpg|thumb|left|Ballast back print part, cut off ballast back]]


Now it have the right shape to use this ballast in the CCFL lamp cap.
[[Image:cut off ballast front.jpg |thumb|center|Ballast front print part, cut off ballast front]]


[[Image:seperated balast print.jpg|thumb|middel|seperated balast print]]
[[Image:take out the ccfl and ballast.JPG|thumb|left|CCFL and ballast|300px]]


If you are lucky you find in some scanners a seperated balast print.


[[Image:G5 T5 tube lamp and CCFL ballast.JPG|thumb|middel|tube lamp and CCFL ballast|300px]]


It is possible to use a CCFL ballast in combination with a normal fluorescent tube lamp.
[[Image:G5 T5 tube lamp and CCFL ballast.JPG|thumb|right|normal tube lamp and CCFL ballast|300px]]
 
[[Image:separated balast print.jpg|thumb|center|separated ballast print]]
 
 
 
 
 
 
 
 
 
 
[[Image:ccfl in old fax.GIF|thumb|middel|CCFL in old FAX]]


== CCFL lamp and ballast out of a fax machine ==
== CCFL lamp and ballast out of a fax machine ==
[[Image:ccfl in old fax.GIF|thumb|right|CCFL in old FAX]]
It is possible to use a CCFL and electronic ballast out off an old fax machine, however some fax machines have a colored CCFL tube
* In some colored CCFL tube faxes it is possible to take the colored film off
*Some colored CCFL tube faxes have colored glass, then the tube is useless for the lamp cap
*The CCFL tube is in the paper scanning part of the fax
*CCFL ballast is connected with the CCFL tube
*Not all fax machines have CCFL technology
*New fax machines and the very old fax machines have LED technology


It is possible to use a CCFL and electronic ballast out of a old fax machine.


Some  fax machine have a colored CCFL tube.


Some colored CCFL tubefax it is possible to take the colored film off.


Some colored CCFL tubefax have colored glas, than the tube is useles for the lamp cap.


== LINKS ==
[[Inverter for fluorescent lamp]]
[[3rd world CCFL lamp (2007 model)]]


The CCFL tube is in the paper scanning part of the fax.
CCFL ballast is conected with the CCFL tube.


Not al fax machine have CCFL technology
== Interwiki links ==
New fax and the verry old fax have led technology


* [[Wikipedia:Cold cathode]]


 
[[Category:3rd world arm lamp]]
--------------------------------------------
----------------------------------------------
 
 
 
 
 
== LINKS ==
-
 
-
[[Inverter for fluorescent lamp]]
 
[[Category:Photovoltaics]]
[[Category:Photovoltaics]]
[[Category:How tos]]
[[Category:How tos]]

Revision as of 01:48, 4 December 2017

Disadvantages Kerosene lamps

  • Kerosene lamps pollute the air, which can lead to health problems
  • Kerosene lamps lose a lot of energy while producing heat

Disadvantages Edison light bulb

  • Glow bulb lamps lose a lot of energy while producing heat and attracts insects

Disadvantages LED lighting

  • LED lighting is very expensive as an alternative to fluorescent tubing though it does offer an increased lamplife of 50,000 run hours (approx 10 years) over a fluorescent tube which is typically 9000 hours. Modern LED alternatives to fluorescent tubing also offer a power saving of about 40-60% though this saving is normally not great enough to pay back the difference in cost between the LED alternative and fluorescent tube over the life of the fitting.

Disadvantages Energy saving fluorescent bulbs lamps

  • Energy saving fluorescent bulbs lamps have a short life and cannot handle vibrations and are expensive
  • Many types contains mercury and other dangerous metals

Advantages Standard fluorescent tubes

  • Standard fluorescent tubes have a long life and are energy efficient and are cheap.

Disadvantages ballast with thyristor

  • Fluorescent bulbs and tubes have a thyristor in the electronic ballast
  • This thyristor spoils a lot of energy producing heat.
  • The base or outlet end of the fluorescent lamp has two filament coils
  • These coils spoil a lot of energy producing heat wen used with a thyristor ballast

Advantages CCFL and EEFL inverter

Wikipedia:CCFL inverter

  • have no thyristor that heat up, but has two transistors.
  • CCFL inverter can work on minimum 6 volt power

Advantages CCFL lamp

  • Smaller, thinner, and more light weight than a known fluorescent lamp.
  • Have no filament coils that heat up, but Cold cathodes.
  • Have a longer life
  • Can better handle vibrations.
  • This makes the CCFL lamp very use full to use in all areas

Advantages EEFL lamp

  • Smaller, thinner and more light weight than a known fluorescent lamp.
  • Have no filament coils that heat up, but External Electrodes.

External Electrodes can easely take lose from the Fluorescent Lamp

  • Have a longer life than CCFL
  • Can better handle vibrations.
  • More EEFL lamps can connect parallel on one EEFL inverter
  • This makes the EEFL lamp very use full to use in poor areas

Advantages CCFL inverter+FL lamp

  • you can use the CCFL inverter to light up a old fluorescent lamp.
  • The inverter use the filament coils like Cold cathodes.
  • Does not Matter if these coils are broken.
  • the end of the fluorescent lamp does not heat up.

Disadvantages CCFL and EEFL

The mercury in the tubes fluorescent-bulbs

Importance of Lamp Cap with the following benefits:

Like the 3rd world CCFL lamp (2007 model) the inverter near the CCFL-tubes-lamps


-Energy efficient

-Protected against falling from heights

-Protected against vibrations

-Protected against impressions

-Water, air and insect tight

-Acceptable design

-Easy to adjust in any direction

-Inexpensive

-Can work on low plus and min (DC) voltage

-can be made partly of recycled materials


CCFL in old document scanner

How to

You can use a CCFL and electronic ballast out of an old SCSI document scanner. Just so you know a ballast is the same as an Inverter. Also not all scanners have CCFL technology the new ones have LED technology and very old black and white faxes have LED technology. You may be lucky enough to find in some scanners a separated CCFL inverter circuit board.

WARNING the CCFL inverter has a dangerous high voltage output

old scanner with CCFL and inverter

Instructions:

  • Make a drawing of the electronic schema
  • Some times you can find a circuit board with the CCFL inverter electronics and some scanning electronics.
  • You have to separate the scanning electronic parts
  • Cut of the CCFL ballast unrelated electronic
  • Now it have the right shape to use this inverter to light up the CCFL lamp.
  • It is possible to use a CCFL inverter in combination with a normal fluorescent tube lamp


Ballast back print part, cut off ballast back
Ballast front print part, cut off ballast front
CCFL and ballast


normal tube lamp and CCFL ballast
File:Separated balast print.jpg
separated ballast print

CCFL lamp and ballast out of a fax machine

CCFL in old FAX

It is possible to use a CCFL and electronic ballast out off an old fax machine, however some fax machines have a colored CCFL tube

  • In some colored CCFL tube faxes it is possible to take the colored film off
  • Some colored CCFL tube faxes have colored glass, then the tube is useless for the lamp cap
  • The CCFL tube is in the paper scanning part of the fax
  • CCFL ballast is connected with the CCFL tube
  • Not all fax machines have CCFL technology
  • New fax machines and the very old fax machines have LED technology



LINKS

Inverter for fluorescent lamp 3rd world CCFL lamp (2007 model)


Interwiki links

Cookies help us deliver our services. By using our services, you agree to our use of cookies.