Table 1 shows the temperature multipliers for several different batteries at different temperatures. | |||
{| border="1" cellpadding="5" | {| border="1" cellpadding="5" | ||
|+'''Table 1. Battery Capacity Temperature Multipliers''' | |+'''Table 1. Battery Capacity Temperature Multipliers''' | ||
Line 27: | Line 28: | ||
| '''45°C''' || - || - || - || - || 1.00 || - | | '''45°C''' || - || - || - || - || 1.00 || - | ||
|} | |} | ||
Temperature multipliers are used when calculating the correct battery size of a solar photovoltaic system. The temperature multiplier for the battery is multiplied by the depth of discharge (DoD) and amp-hour (Ah) demand to obtain the needed battery storage of your system. | |||
These values were obtained from 3rd and 4th Edition of Thomas B. Reddy's Battery Handbooks, [https://enphase.com/sites/default/files/downloads/support/Tech-Brief-AC-Battery-Params-NREL-SAM-EN-US.pdf], and [http://www.a-ghadimi.com/files/Courses/Renewable%20Energy/REN_Book.pdf]. | |||
See [[Help:Tables]]. | See [[Help:Tables]]. |
Revision as of 20:18, 18 January 2020
Introduction
Describe what battery capacity means in this context.
Tables
Table 1 shows the temperature multipliers for several different batteries at different temperatures.
Temp (°C) | Zinc-Chloride | Portable Sealed NiMH (2C) | Iron-Electrode (C/10) low rate extended life design | Rechargable zinc/Alkaline/Mangenese Dioxide 50-100mA | General AC Battery | Lead Acid C/20 |
---|---|---|---|---|---|---|
-30°C | - | - | - | - | - | 0.52 |
-20°C | - | - | - | - | 0.80 | 0.64 |
-10°C | 0.60 | 0.50 | 0.50 | 0.55 | - | 0.76 |
0°C | 0.80 | 0.80 | 0.70 | 0.75 | 0.95 | 0.85 |
10°C | 0.97 | 0.85 | 0.90 | 0.85 | 1.00 | 0.92 |
20°C | 1.00 | 0.90 | 1.00 | 0.95 | - | 0.98 |
25°C | - | - | - | - | 1.00 | - |
30°C | 1.10 | 0.95 | 1.00 | 1.00 | - | 1.02 |
40°C | 1.15 | 1.00 | 1.00 | 1.00 | - | 1.04 |
45°C | - | - | - | - | 1.00 | - |
Temperature multipliers are used when calculating the correct battery size of a solar photovoltaic system. The temperature multiplier for the battery is multiplied by the depth of discharge (DoD) and amp-hour (Ah) demand to obtain the needed battery storage of your system. These values were obtained from 3rd and 4th Edition of Thomas B. Reddy's Battery Handbooks, [1], and [2].
See Help:Tables.
Use help:references to see how to use the reference format.[1]
Use Help:Images on how to upload the graph image(s). Please remember to use a very descriptive name for the file.
References
- ↑ It is quite easy and just relies on ref and /ref in between less than and greater than symbols.